Assessment Year | 1985 |
---|---|
Principal Product | RATCHETS & WRENCHES |
NAICS |
n/a
|
SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
Sales Range | $1 M to 5M |
# of Employees | 25 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $15,169 | 177,022 |
kWh
|
$0.086 |
Natural Gas | $7,988 | 1,147 |
MMBtu
|
$6.96 |
Fuel Oil #2 | $10,993 | 1,400 |
MMBtu
|
$7.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,131 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,131 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $466 | $200 | - | - |
$466
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $106 | $165 |
$106
1,172
kWh
|
- | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $3,605 | - | - |
$244
-
MMBtu
|
$3,361
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $954 | $114 |
$954
11,137
kWh
|
- | - | |
TOTAL RECOMMENDED | $5,131 | $479 |
$1,060
12,309
kWh
|
$244
-
MMBtu
|
$3,827
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,131 | $479 |
$1,060
12,309
kWh
|
$244
-
MMBtu
|
$3,827
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs