Assessment Year | 1984 |
---|---|
Principal Product | ELECTRONIC COILS |
NAICS |
n/a
|
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 3,150
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,294 | 383,060 |
kWh
|
$0.074 |
Natural Gas | $12,743 | 2,086 |
MMBtu
|
$6.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,095 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $702 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6214: Shut off pilots in standby equipment | $79 | - | - |
$79
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $359 | $209 |
$359
4,982
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,034 | $90 |
$1,034
14,068
kWh
|
- | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $623 | $1,079 |
$1,179
16,120
kWh
|
$(-556.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $2,095 | $1,378 |
$2,572
35,170
kWh
|
$(-477.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $702 | $1,079 |
$1,179
16,120
kWh
|
$(-477.0)
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs