| Assessment Year | 1984 |
|---|---|
| Principal Product | ANODIZING OF METALS |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $1 M to 5M |
| # of Employees | 35 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 5,160
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $48,355 | 599,941 |
kWh
|
$0.081 |
| Natural Gas | $78,669 | 11,467 |
MMBtu
|
$6.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,908 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,908 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,297 | $400 | - |
$3,297
-
MMBtu
|
|
| 02 | 2.2511: Insulate bare equipment | $2,850 | $1,872 | - |
$2,850
-
MMBtu
|
|
| 03 | 2.2113: Repair or replace steam traps | $4,985 | $1,125 | - |
$4,985
-
MMBtu
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $776 | $125 |
$776
9,672
kWh
|
- | |
| TOTAL RECOMMENDED | $11,908 | $3,522 |
$776
9,672
kWh
|
$11,132
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,908 | $3,522 |
$776
9,672
kWh
|
$11,132
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs