| Assessment Year | 2026 |
|---|---|
| Principal Product | S.E.T (Surface Enhancement Technology) Wear Materials |
| NAICS | 332312: Fabricated Structural Metal Manufacturing |
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 42 |
| Plant Area |
86,865
ft2
|
| Annual Production | 15,000
units
|
| Production Hrs. Annual | 2,548
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $30,769 | 278,370 |
kWh
|
$0.11 | |
| Electricity Demand | $20,470 | 2,363 |
kW-mo/yr
|
$8.66 | |
| Natural Gas | $284 | 7 |
MMBtu
|
$40.81 | |
| LPG | $3,177 | 132 |
MMBtu
|
$24.03 | |
| Other Gas | $11,597 | 357 |
MMBtu
|
$32.52 | |
| Waste Disposal Costs | |||||
| Other Liquid (non-haz) | $2,893 | 1 |
gal
|
$2,893.33 | |
| TOTAL YEARLY COSTS | $69,191 | ||||
| RECOMMENDED SAVINGS* | $150,301 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.426: Modify workload | $6,666 | $9,600 | - | - |
$426
-
MMBtu
|
$6,240 | - | - | |
| 02 | 4.515: Install shelves / racks to utilize unused space | $140,000 | $32,760 | - | - | - | - | - | $140,000 | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $474 | $132 |
$428
3,893
kWh
|
$46
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.6218: Turn off equipment when not in use | $3,161 | $918 |
$2,485
22,593
kWh
|
$659
-
kW-mo/yr
|
- | - | $17 | - | |
| TOTAL RECOMMENDED | $150,301 | $43,410 |
$2,913
26,486
kWh
|
$705
-
kW-mo/yr
|
$426
-
MMBtu
|
$6,240 | $17 | $140,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs