| Assessment Year | 2026 |
|---|---|
| Principal Product | Titanium tube & Nickel alloys |
| NAICS | 331491: Nonferrous Metal (except Copper and Aluminum) Rolling, Drawing, and Extruding |
| SIC | 3356: Rolling, Drawing, and Extruding of Nonferrous Metals, Except Copper and Aluminum |
| Sales Range | $50 M to 100M |
| # of Employees | 204 |
| Plant Area |
240,000
ft2
|
| Annual Production | 36,000
thousand feet
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $450,452 | 12,346,548 |
kWh
|
$0.036 | |
| Electricity Demand | $446,732 | 811,935 |
kW-mo/yr
|
$0.55 | |
| Waste Disposal Costs | |||||
| Water Usage | $10,796 | 3,182 |
Tgal
|
$3.39 | |
| Water Disposal | $207 | 3,182 |
Tgal
|
$0.065 | |
| TOTAL YEARLY COSTS | $908,187 | ||||
| RECOMMENDED SAVINGS* | $440,230 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $7,201 | - |
$7,055
193,285
kWh
|
$146
-
kW-mo/yr
|
- | - | |
| 02 | 2.9114: Use solar heat to make electricty | $21,801 | $328,991 |
$21,801
597,282
kWh
|
- | - | - | |
| 03 | 2.7135: Install occupancy sensors | $2,834 | $3,130 |
$2,714
74,367
kWh
|
$119
-
kW-mo/yr
|
- | - | |
| 04 | 4.112: Replace old machine with new automatic multi-station tool | $394,200 | $2,500,751 | - | - | - | $394,200 | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,016 | $245 |
$1,016
27,833
kWh
|
- | - | - | |
| 06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $13,178 | $19,400 |
$(-3.4)
(-95)
kWh
|
- | $(-2,600.0) | $15,782 | |
| TOTAL RECOMMENDED | $440,230 | $2,852,517 |
$32,583
892,672
kWh
|
$265
-
kW-mo/yr
|
$(-2,600.0) | $409,982 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs