Assessment Year | 2025 |
---|---|
Principal Product | gasoline service station |
NAICS | 447110: Gasoline Stations with Convenience Stores |
SIC | 5541: Gasoline Service Stations |
Sales Range | $1 M to 5M |
# of Employees | 8 |
Plant Area |
91,443
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $31,911 | 591,424 |
kWh
|
$0.054 | |
Electricity Demand | $24,755 | 1,577 |
kW-mo/yr
|
$15.70 | |
Electricity Fees | $5,079 | - |
|
- | |
Natural Gas | $1,804 | 124 |
MMBtu
|
$14.55 | |
Waste Disposal Costs | |||||
Water Usage | $5,146 | 386 |
Tgal
|
$13.33 | |
Water Disposal | $594 | 386 |
Tgal
|
$1.54 | |
TOTAL YEARLY COSTS | $69,289 | ||||
RECOMMENDED SAVINGS* | $7,835 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $171 | $179 |
$171
3,165
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $998 | $1,151 |
$665
12,324
kWh
|
$333
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,935 | $848 |
$1,280
23,718
kWh
|
$655
-
kW-mo/yr
|
|
04 | 2.7232: Replace existing hvac unit with high efficiency model | $4,732 | $29,880 |
$2,210
40,960
kWh
|
$2,522
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $7,835 | $32,057 |
$4,326
80,166
kWh
|
$3,510
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs