Assessment Year | 2024 |
---|---|
Principal Product | Marine Winches |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
50,000
ft2
|
Annual Production | 1,920
units
|
Production Hrs. Annual | 2,800
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $38,199 | 486,560 |
kWh
|
$0.079 | |
Electricity Demand | $32,949 | 2,596 |
kW-mo/yr
|
$12.69 | |
Waste Disposal Costs | |||||
Water Usage | $2,003 | 626 |
Tgal
|
$3.20 | |
Water Disposal | $1,943 | 626 |
Tgal
|
$3.10 | |
TOTAL YEARLY COSTS | $75,094 | ||||
RECOMMENDED SAVINGS* | $13,380 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,127 | $2,110 |
$1,127
7,617
kWh
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $976 | $888 |
$515
6,521
kWh
|
$477
-
kW-mo/yr
|
$(-16.1) | |
03 | 4.426: Modify workload | $11,276 | $320 |
$11,276
11,276
kWh
|
- | - | |
TOTAL RECOMMENDED | $13,380 | $3,318 |
$12,919
25,413
kWh
|
$477
-
kW-mo/yr
|
$(-16.1) | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs