Assessment Year | 1988 |
---|---|
Principal Product | MOLDED WOODEN PLUGS |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $500 k to 1M |
# of Employees | 25 |
Plant Area |
n/a
|
Annual Production | 412
ton
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $36,210 | 501,172 |
kWh
|
$0.072 |
Natural Gas | $7,863 | 1,419 |
MMBtu
|
$5.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,130 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,707 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,390 | - |
$1,390
27,843
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $343 | $507 |
$343
5,862
kWh
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $423 | - |
$423
6,741
kWh
|
- | - | |
04 | 2.7231: Use radiant heater for spot heating | $1,760 | $1,860 | - |
$1,760
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $214 | $66 |
$232
3,810
kWh
|
- | $(-18.0) | |
TOTAL RECOMMENDED | $4,130 | $2,433 |
$2,388
44,256
kWh
|
$1,760
-
MMBtu
|
$(-18.0) | ||
TOTAL IMPLEMENTED | $3,707 | $2,433 |
$1,965
37,515
kWh
|
$1,760
-
MMBtu
|
$(-18.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs