| Assessment Year | 1988 |
|---|---|
| Principal Product | LAMINATED FLOORING |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $5 M to 10M |
| # of Employees | 115 |
| Plant Area |
n/a
|
| Annual Production | 2,500
thousand feet
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $213,675 | 3,074,443 |
kWh
|
$0.070 |
| Wood | $2,747 | 100,173 |
MMBtu
|
$0.027 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,203 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $807 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3192: Use fossil fuel powered generator during peak demand periods | $10,023 | $14,000 |
$10,500
184,349
kWh
|
$(-477.0)
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $390 | $1,131 |
$390
6,741
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,373 | - |
$2,373
41,618
kWh
|
- | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $310 | - |
$310
6,448
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $62 | $231 |
$62
1,172
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $45 | $641 |
$45
879
kWh
|
- | |
| TOTAL RECOMMENDED | $13,203 | $16,003 |
$13,680
241,207
kWh
|
$(-477.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $807 | $2,003 |
$807
15,240
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Wood Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs