| Assessment Year | 1987 |
|---|---|
| Principal Product | RAILROAD TANK CAR REFURBISHMENT |
| NAICS |
n/a
|
| SIC | 3799: Transportation Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 98 |
| Plant Area |
n/a
|
| Annual Production | 2,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $132,208 | 2,366,940 |
kWh
|
$0.056 |
| LPG | $95,218 | 34,716 |
MMBtu
|
$2.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,997 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,730 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,860 | $1,200 | - |
$1,860
-
MMBtu
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $693 | $1,071 |
$693
14,361
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,177 | $339 |
$1,177
25,791
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $267 | $99 |
$353
7,913
kWh
|
- | $(-86.0) | |
| TOTAL RECOMMENDED | $3,997 | $2,709 |
$2,223
48,065
kWh
|
$1,860
-
MMBtu
|
$(-86.0) | ||
| TOTAL IMPLEMENTED | $3,730 | $2,610 |
$1,870
40,152
kWh
|
$1,860
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs