Assessment Year | 1986 |
---|---|
Principal Product | PRESTRESSED CONCRETE |
NAICS |
n/a
|
SIC | 3272: Concrete Products, Except Block and Brick |
Sales Range | $1 M to 5M |
# of Employees | 25 |
Plant Area |
n/a
|
Annual Production | 27,000
thousand feet
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $17,226 | 138,042 |
kWh
|
$0.12 |
Natural Gas | $72,564 | 16,933 |
MMBtu
|
$4.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,902 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,107 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,910 | - |
$3,910
47,479
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $575 | - |
$575
7,034
kWh
|
- | - | |
03 | 2.2515: Use optimum thickness insulation | $11,458 | $28,763 | - |
$9,438
-
MMBtu
|
$2,020 | |
05 | 2.2135: Repair and eliminate steam leaks | $2,214 | $2,000 | - |
$2,214
-
MMBtu
|
- | |
06 | 2.1232: Keep boiler tubes clean | $1,737 | $3,000 | - |
$1,737
-
MMBtu
|
- | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $3,600 | $10,000 | - |
$3,600
-
MMBtu
|
- | |
08 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $408 | $1,000 | - |
$408
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $23,902 | $44,763 |
$4,485
54,513
kWh
|
$17,397
-
MMBtu
|
$2,020 | ||
TOTAL IMPLEMENTED | $7,107 | $3,000 |
$4,485
54,513
kWh
|
$2,622
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs