| Assessment Year | 1985 |
|---|---|
| Principal Product | RICE |
| NAICS |
n/a
|
| SIC | 2044: Rice Milling |
| Sales Range | $50 M to 100M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $939,300 | 19,048,066 |
kWh
|
$0.049 |
| Natural Gas | $391,979 | 102,466 |
MMBtu
|
$3.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $41,070 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,377 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,407 | - | - |
$2,007
-
MMBtu
|
$(-600.0) | |
| 02 | 2.2425: Use flue gases to heat process or service water | $19,893 | $35,000 | - |
$19,893
-
MMBtu
|
- | |
| 03 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $11,720 | $10,000 | - |
$11,720
-
MMBtu
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,800 | $1,416 |
$6,800
138,628
kWh
|
- | - | |
| 05 | 2.7261: Install timers and/or thermostats | $1,250 | $450 |
$766
17,585
kWh
|
$484
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $41,070 | $46,866 |
$7,566
156,213
kWh
|
$34,104
-
MMBtu
|
$(-600.0) | ||
| TOTAL IMPLEMENTED | $14,377 | $10,450 |
$766
17,585
kWh
|
$14,211
-
MMBtu
|
$(-600.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs