Assessment Year | 1985 |
---|---|
Principal Product | SAND FOR GLASSMAKING |
NAICS |
n/a
|
SIC | 3295: Minerals and Earths, Ground or Otherwise Treated |
Sales Range | $1 M to 5M |
# of Employees | 29 |
Plant Area |
n/a
|
Annual Production | 97,400
ton
|
Production Hrs. Annual | 3,200
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,895 | 1,602,872 |
kWh
|
$0.076 |
Natural Gas | $59,712 | 31,001 |
MMBtu
|
$1.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,751 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,751 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,755 | $1,167 |
$1,755
28,429
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $821 | $88 |
$821
10,551
kWh
|
- | |
03 | 2.2211: Use optimum temperature | $5,175 | $15,000 | - |
$5,175
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,751 | $16,255 |
$2,576
38,980
kWh
|
$5,175
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,751 | $16,255 |
$2,576
38,980
kWh
|
$5,175
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs