| Assessment Year | 1985 |
|---|---|
| Principal Product | PELLETIZED BOILER FUEL |
| NAICS |
n/a
|
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $500 k to 1M |
| # of Employees | 15 |
| Plant Area |
n/a
|
| Annual Production | 15,750
ton
|
| Production Hrs. Annual | 3,840
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $69,793 | 1,087,925 |
kWh
|
$0.064 |
| Natural Gas | $206,639 | 47,751 |
MMBtu
|
$4.33 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $29,776 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,974 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $442 | $666 |
$442
8,792
kWh
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $26,802 | $44,960 |
$(-2,824.0)
(-57,737)
kWh
|
$29,626
-
MMBtu
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,787 | $642 |
$867
16,999
kWh
|
- | $920 | |
| 04 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $745 | $1,752 | - |
$745
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $29,776 | $48,020 |
$(-1,515.0)
(-31,946)
kWh
|
$30,371
-
MMBtu
|
$920 | ||
| TOTAL IMPLEMENTED | $2,974 | $3,060 |
$1,309
25,791
kWh
|
$745
-
MMBtu
|
$920 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs