Assessment Year | 1984 |
---|---|
Principal Product | STEEL CASTINGS |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 267 |
Plant Area |
n/a
|
Annual Production | 6,000
ton
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $664,901 | 10,852,872 |
kWh
|
$0.061 |
Natural Gas | $268,840 | 62,193 |
MMBtu
|
$4.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $113,094 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $113,094 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $75,700 | $1,000 | - |
$75,700
-
MMBtu
|
|
02 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $2,320 | $332 | - |
$2,320
-
MMBtu
|
|
03 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $674 | $1,525 | - |
$674
-
MMBtu
|
|
04 | 2.3212: Optimize plant power factor | $25,600 | $15,000 |
$25,600
-
kWh
|
- | |
05 | 2.3212: Optimize plant power factor | $8,800 | $840 |
$8,800
-
kWh
|
- | |
TOTAL RECOMMENDED | $113,094 | $18,697 |
$34,400
-
kWh
|
$78,694
-
MMBtu
|
||
TOTAL IMPLEMENTED | $113,094 | $18,697 |
$34,400
-
kWh
|
$78,694
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs