Assessment Year | 2025 |
---|---|
Principal Product | Treated Municipal Wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $1 M to 5M |
# of Employees | 7 |
Plant Area |
707,731
ft2
|
Annual Production | 3,800
Tgal
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $259,078 | 2,324,235 |
kWh
|
$0.11 |
TOTAL YEARLY COSTS | $259,078 | |||
RECOMMENDED SAVINGS* | $60,176 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $292 | $510 |
$292
2,628
kWh
|
|
02 | 4.662: Level one – add communication using iiot devices to existing control system to modify operations | $23,606 | $141,000 |
$23,606
212,671
kWh
|
|
03 | 2.9114: Use solar heat to make electricty | $36,278 | $403,650 |
$36,278
326,829
kWh
|
|
TOTAL RECOMMENDED | $60,176 | $545,160 |
$60,176
542,128
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs