Assessment Year 2025
Principal Product Treated Municipal Wastewater
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $1
M
to 5
M
# of Employees 7
Plant Area 707,731
ft2
Annual Production 3,800
Tgal
Production Hrs. Annual 2,080
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $259,078 2,324,235
kWh
TOTAL YEARLY COSTS $259,078
RECOMMENDED SAVINGS* $60,176 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $292 $510 $292
2,628
kWh
02 4.662: Level one – add communication using iiot devices to existing control system to modify operations $23,606 $141,000 $23,606
212,671
kWh
03 2.9114: Use solar heat to make electricty $36,278 $403,650 $36,278
326,829
kWh
TOTAL RECOMMENDED $60,176 $545,160 $60,176
542,128
kWh
TOTAL IMPLEMENTED - - -