Assessment Year | 2025 |
---|---|
Principal Product | Water Purification System |
NAICS | 333249: Other Industrial Machinery Manufacturing |
SIC | 3625: Relays and Industrial Controls |
Sales Range | $50 M to 100M |
# of Employees | 235 |
Plant Area |
100,000
ft2
|
Annual Production | 85
units
|
Production Hrs. Annual | 6,500
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,987 | 1,389,200 |
kWh
|
$0.070 |
Electricity Demand | $150,890 | 10,039 |
kW-mo/yr
|
$15.03 |
Natural Gas | $61,275 | 7,363 |
MMBtu
|
$8.32 |
LPG | $4,803 | 97 |
MMBtu
|
$49.52 |
TOTAL YEARLY COSTS | $313,955 | |||
RECOMMENDED SAVINGS* | $83,261 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,432 | $1,275 |
$891
12,730
kWh
|
$541
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 4.322: Eliminate old stock and modify inventory control | $16,150 | $25,000 | - | - | - | - | $9,750 | $6,400 | - | |
03 | 2.7425: Clean or color roof to reduce solar load | $6,381 | $25,002 |
$6,381
91,157
kWh
|
- | - | - | - | - | - | |
04 | 2.1224: Replace boiler | $31,301 | $143,295 | - | - |
$5,051
-
MMBtu
|
- | - | - | $26,250 | |
05 | 2.1321: Replace fossil fuel equipment with electrical equipment | $27,997 | $144,549 |
$(-786.0)
(-11,232)
kWh
|
- | - |
$4,783
-
MMBtu
|
$24,000 | - | - | |
TOTAL RECOMMENDED | $83,261 | $339,121 |
$6,486
92,655
kWh
|
$541
-
kW-mo/yr
|
$5,051
-
MMBtu
|
$4,783
-
MMBtu
|
$33,750 | $6,400 | $26,250 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs