Assessment Year | 2001 |
---|---|
Principal Product | Aluminum Extruded Products for Aircraft Applications |
NAICS |
n/a
|
SIC | 3354: Aluminum Extruded Products |
Sales Range | $10 M to 50M |
# of Employees | 124 |
Plant Area |
35,000
ft2
|
Annual Production | 21,000,000
lb
|
Production Hrs. Annual | 5,400
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $388,530 | 12,951,000 |
kWh
|
$0.030 |
Electricity Demand | $294,942 | 45,374 |
kW-mo/yr
|
$6.50 |
Electricity Fees | $50,494 | - |
|
- |
Natural Gas | $221,652 | 66,407 |
MMBtu
|
$3.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $92,066 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,069 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Primary Product Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $5,069 | $2,460 |
$5,069
158,400
kWh
|
- | - | - | - | |
02 | 2.4314: Use synthetic lubricant | $4,652 | $694 |
$1,313
40,747
kWh
|
$473
-
kW-mo/yr
|
$2,866
-
gal
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $618 | $618 |
$453
14,174
kWh
|
$165
-
kW-mo/yr
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $3,710 | $3,532 |
$2,727
85,204
kWh
|
$983
-
kW-mo/yr
|
- | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,330 | $60 | - | - | - | - | $2,330 | |
06 | 3.6192: Use a less expensive method of waste removal | $2,727 | $60 | - | - | - | - | $2,727 | |
07 | 4.431: Train operators for maximum operating efficiency | $71,280 | $5,645 | - | - | - | $71,280 | - | |
08 | 4.621: Use fixtures to reduce machine changeout times | $1,680 | $390 | - | - | - | $1,680 | - | |
TOTAL RECOMMENDED | $92,066 | $13,459 |
$9,562
298,525
kWh
|
$1,621
-
kW-mo/yr
|
$2,866
-
gal
|
$72,960 | $5,057 | ||
TOTAL IMPLEMENTED | $5,069 | $2,460 |
$5,069
158,400
kWh
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Primary Product Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs