Assessment Year 2025
Principal Product Industrial Coated Fabrics
NAICS 313320: Fabric Coating Mills
SIC 2295: Coated Fabrics, Not Rubberized
Sales Range $5
M
to 10
M
# of Employees 46
Plant Area 72,500
ft2
Annual Production 1
units
Production Hrs. Annual 4,420
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $170,940 1,406,400
kWh
Natural Gas $83,230 5,564
MMBtu
TOTAL YEARLY COSTS $254,170
RECOMMENDED SAVINGS* $99,863 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,596 $135 $1,596
13,081
kWh
-
02 2.7135: Install occupancy sensors $4,511 $500 $4,511
36,978
kWh
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $427 $50 $427
3,504
kWh
-
04 2.1116: Improve combustion control capability $24,849 $20,250 - $24,849
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $5,396 $9,990 $5,396
44,227
kWh
-
06 2.3513: Consider power loss as well as initial loads and load growth in down-sizing transformers $3,451 $15,964 $3,451
28,288
kWh
-
07 2.9114: Use solar heat to make electricty $51,703 $514,800 $51,703
423,797
kWh
-
08 2.7232: Replace existing hvac unit with high efficiency model $7,930 $80,003 $7,930
65,000
kWh
-
TOTAL RECOMMENDED $99,863 $641,692 $75,014
614,875
kWh
$24,849
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs