| Assessment Year | 2024 |
|---|---|
| Principal Product | Water Supply |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $100 M to 500M |
| # of Employees | 245 |
| Plant Area |
1,800,000
ft2
|
| Annual Production | 18,250,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $907,741 | 11,774,400 |
kWh
|
$0.077 |
| Electricity Demand | $248,913 | 26,287 |
kW-mo/yr
|
$9.47 |
| Natural Gas | $692,890 | 121,815 |
MMBtu
|
$5.69 |
| TOTAL YEARLY COSTS | $1,849,544 | |||
| RECOMMENDED SAVINGS* | $358,383 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $358,383 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $310,598 | $83,380 |
$310,598
4,033,739
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $10,098 | $41,000 |
$10,098
131,140
kWh
|
- | |
| 03 | 2.9114: Use solar heat to make electricty | $37,687 | $514,800 |
$34,253
444,845
kWh
|
$3,434 | |
| TOTAL RECOMMENDED | $358,383 | $639,180 |
$354,949
4,609,724
kWh
|
$3,434 | ||
| TOTAL IMPLEMENTED | $358,383 | $639,180 |
$354,949
4,609,724
kWh
|
$3,434 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs