Assessment Year 2024
Principal Product Water Supply
NAICS 221310: Water Supply and Irrigation Systems
SIC 4941: Water Supply
Sales Range $100
M
to 500
M
# of Employees 245
Plant Area 1,800,000
ft2
Annual Production 18,250,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $907,741 11,774,400
kWh
Electricity Demand $248,913 26,287
kW-mo/yr
Natural Gas $692,890 121,815
MMBtu
TOTAL YEARLY COSTS $1,849,544
RECOMMENDED SAVINGS* $358,383 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings One-time Revenue or Avoided Cost Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $310,598 $83,380 $310,598
4,033,739
kWh
-
02 2.4133: Use most efficient type of electric motors $10,098 $41,000 $10,098
131,140
kWh
-
03 2.9114: Use solar heat to make electricty $37,687 $514,800 $34,253
444,845
kWh
$3,434
TOTAL RECOMMENDED $358,383 $639,180 $354,949
4,609,724
kWh
$3,434
TOTAL IMPLEMENTED - - - -