Assessment Year | 2024 |
---|---|
Principal Product | Metal mill |
NAICS | 335314: Relay and Industrial Control Manufacturing |
SIC | 3625: Relays and Industrial Controls |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
448,542
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 2,938
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,153,120 | 9,314,880 |
kWh
|
$0.12 |
Electricity Demand | $717,117 | 81,091 |
kW-mo/yr
|
$8.84 |
TOTAL YEARLY COSTS | $1,870,237 | |||
RECOMMENDED SAVINGS* | $145,459 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,967 | $75 |
$1,967
15,865
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $34,951 | $21,000 |
$34,951
281,862
kWh
|
- | |
03 | 2.4224: Upgrade controls on compressors | $4,159 | $12,500 |
$4,159
33,540
kWh
|
- | |
04 | 2.9114: Use solar heat to make electricty | $104,382 | $480,480 |
$50,307
405,702
kWh
|
$54,075
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $145,459 | $514,055 |
$91,384
736,969
kWh
|
$54,075
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs