Assessment Year | 2022 |
---|---|
Principal Product | Polytetrafluoroethylene |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 28 |
Plant Area |
110,000
ft2
|
Annual Production | 1,200
ton
|
Production Hrs. Annual | 2,990
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $140,450 | 1,830,280 |
kWh
|
$0.077 |
Electricity Demand | $25,066 | 6,141 |
kW-mo/yr
|
$4.08 |
Natural Gas | $2,658 | 351 |
MMBtu
|
$7.57 |
TOTAL YEARLY COSTS | $168,174 | |||
RECOMMENDED SAVINGS* | $7,743 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,722 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2694: Use highest temperature for chilling or cold storage | $1,066 | $10 |
$1,066
13,891
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,014 | $25 |
$1,014
13,216
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,034 | $630 |
$4,034
52,566
kWh
|
- | |
04 | 2.2625: Chill water to the highest temperature possible | $336 | $250 |
$336
4,383
kWh
|
- | |
05 | 2.7135: Install occupancy sensors | $21 | $25 |
$21
270
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,272 | $2,688 |
$1,011
13,179
kWh
|
$261
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $7,743 | $3,628 |
$7,482
97,505
kWh
|
$261
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $7,722 | $3,603 |
$7,461
97,235
kWh
|
$261
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs