| Assessment Year | 2021 |
|---|---|
| Principal Product | Railroad Tank Cars |
| NAICS | 336510: Railroad Rolling Stock Manufacturing |
| SIC | 3743: Railroad Equipment |
| Sales Range | less than $500 k |
| # of Employees | 350 |
| Plant Area |
1,000,000
ft2
|
| Annual Production | 2,080
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $914,006 | 21,106,476 |
kWh
|
$0.043 | |
| Electricity Demand | $822,484 | 62,785 |
kW-mo/yr
|
$13.10 | |
| Natural Gas | $836,685 | 224,337 |
MMBtu
|
$3.73 | |
| Waste Disposal Costs | |||||
| Water Usage | $10,876 | 1,756 |
Tgal
|
$6.19 | |
| TOTAL YEARLY COSTS | $2,584,051 | ||||
| RECOMMENDED SAVINGS* | $411,402 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $12,423 | $150 |
$12,423
286,876
kWh
|
- | - | - | |
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $67,360 | $13,000 | - |
$67,360
-
kW-mo/yr
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,236 | $1,080 |
$5,236
120,903
kWh
|
- | - | - | |
| 04 | 2.7135: Install occupancy sensors | $1,978 | $559 |
$1,978
45,677
kWh
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $235,346 | $155,805 |
$148,357
3,425,898
kWh
|
$86,989
-
kW-mo/yr
|
- | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $324 | $970 |
$324
7,479
kWh
|
- | - | - | |
| 07 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $75,962 | $304,000 | - | - | - |
$75,962
-
MMBtu
|
|
| 08 | 2.3212: Optimize plant power factor | $8,178 | $56,728 | - | - | $8,178 | - | |
| 09 | 2.4322: Use or replace with energy efficient substitutes | $4,595 | $34,100 |
$4,595
106,102
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $411,402 | $566,392 |
$172,913
3,992,935
kWh
|
$154,349
-
kW-mo/yr
|
$8,178 |
$75,962
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs