Assessment Year 2018
Principal Product Ship Repairing
NAICS 336611: Ship Building and Repairing
SIC 3731: Ship Building and Repairing
Sales Range $1
M
to 5
M
# of Employees 39
Plant Area 540,000
ft2
Annual Production 1,000,000
units
Production Hrs. Annual 4,420
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $89,173 1,027,293
kWh
Electricity Demand $10,994 3,199
kW-mo/yr
TOTAL YEARLY COSTS $100,167
RECOMMENDED SAVINGS* $6,431 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,265

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings
01 2.6218: Turn off equipment when not in use $379 - $379
4,368
kWh
-
02 4.322: Eliminate old stock and modify inventory control $1,300 $200 - $1,300
03 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $4,166 $2,667 $4,166
47,989
kWh
-
04 2.7134: Use photocell controls $427 $400 $427
4,921
kWh
-
05 2.7135: Install occupancy sensors $159 $550 $159
1,827
kWh
-
TOTAL RECOMMENDED $6,431 $3,817 $5,131
59,105
kWh
$1,300
TOTAL IMPLEMENTED $2,265 $1,150 $965
11,116
kWh
$1,300
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs