Assessment Year 2025
Principal Product Elementary School
NAICS 611110: Elementary and Secondary Schools
SIC 8211: Elementary and Secondary Schools
Sales Range less than $500
k
# of Employees 37
Plant Area 49,000
ft2
Annual Production 1
units
Production Hrs. Annual 3,024
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $46,583 441,133
kWh
Electricity Demand $7,979 1,943
kW-mo/yr
TOTAL YEARLY COSTS $54,562
RECOMMENDED SAVINGS* $17,423 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7211: Clean and maintain refrigerant condensers and towers $4,466 $420 $4,466
42,136
kWh
-
02 2.7135: Install occupancy sensors $4,172 $600 $4,172
39,357
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $7,312 $4,476 $6,339
59,802
kWh
$973
-
kW-mo/yr
04 2.7232: Replace existing hvac unit with high efficiency model $1,473 $15,800 $1,473
13,896
kWh
-
TOTAL RECOMMENDED $17,423 $21,296 $16,450
155,191
kWh
$973
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs