ITAC Assessment: LS0325
ITAC logo
ITAC Assessment: LS0325
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Business Association
NAICS 813910: Business Associations
SIC 8611: Business Associations
Sales Range less than $500
k
# of Employees 7
Plant Area 50,771
ft2
Annual Production 1
units
Production Hrs. Annual 8,760
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,270 423,800
kWh
Electricity Demand $4,730 1,149
kW-mo/yr
TOTAL YEARLY COSTS $41,000
RECOMMENDED SAVINGS* $11,218 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7211: Clean and maintain refrigerant condensers and towers $2,309 - $2,309
26,844
kWh
-
02 2.7135: Install occupancy sensors $2,040 $325 $2,040
23,725
kWh
-
03 2.7226: Use computer programs to optimize hvac performance $3,063 $2,380 $3,063
35,618
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $3,806 $4,618 $3,571
41,522
kWh
$235
-
kW-mo/yr
TOTAL RECOMMENDED $11,218 $7,323 $10,983
127,709
kWh
$235
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs