| Assessment Year | 2022 |
|---|---|
| Principal Product | Hotel |
| NAICS | 721110: Hotels (except Casino Hotels) and Motels |
| SIC | 7011: Hotels and Motels |
| Sales Range | less than $500 k |
| # of Employees | 50 |
| Plant Area |
53,417
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $183,932 | 2,279,000 |
kWh
|
$0.081 |
| Electricity Demand | $50,919 | 4,567 |
kW-mo/yr
|
$11.15 |
| Natural Gas | $31,132 | 2,775 |
MMBtu
|
$11.22 |
| TOTAL YEARLY COSTS | $265,983 | |||
| RECOMMENDED SAVINGS* | $31,624 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $31,624 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $106 | $157 |
$106
1,314
kWh
|
- | |
| 02 | 2.1224: Replace boiler | $17,372 | $62,400 | - |
$17,372
-
MMBtu
|
|
| 03 | 2.7226: Use computer programs to optimize hvac performance | $14,146 | $54,880 |
$14,146
174,645
kWh
|
- | |
| TOTAL RECOMMENDED | $31,624 | $117,437 |
$14,252
175,959
kWh
|
$17,372
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $31,624 | $117,437 |
$14,252
175,959
kWh
|
$17,372
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs