ITAC Assessment: LS0012
ITAC logo
ITAC Assessment: LS0012
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2017
Principal Product Ground Coffee
NAICS 311920: Coffee and Tea Manufacturing
SIC 2095: Roasted Coffee
Sales Range $100
M
to 500
M
# of Employees 400
Plant Area 503,700
ft2
Annual Production 41,000
units
Production Hrs. Annual 8,760
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,121,771 16,083,000
kWh
Electricity Demand $228,032 29,372
kW-mo/yr
Natural Gas $945,988 256,365
MMBtu
TOTAL YEARLY COSTS $2,295,791
RECOMMENDED SAVINGS* $85,612 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1243: Use heat from boiler blowdown to preheat boiler feed water $28,766 $12,000 - $28,766
-
MMBtu
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,205 $920 $2,205
31,608
kWh
-
03 2.2511: Insulate bare equipment $993 $548 - $993
-
MMBtu
04 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $21,748 $15,200 $21,748
311,801
kWh
-
05 2.1241: Reduce excessive boiler blowdown $3,685 $4,250 - $3,685
-
MMBtu
06 2.7425: Clean or color roof to reduce solar load $28,215 $80,000 $28,215
404,804
kWh
-
TOTAL RECOMMENDED $85,612 $112,918 $52,168
748,213
kWh
$33,444
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs