| Assessment Year | 2006 |
|---|---|
| Principal Product | comm. & countermeasures |
| NAICS | 334111: Electronic Computer Manufacturing |
| SIC | 3571: Electronic Computers |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
110,000
ft2
|
| Annual Production | 1,500
pieces
|
| Production Hrs. Annual | 6,745
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $232,781 | 2,973,835 |
kWh
|
$0.078 |
| Electricity Demand | $148,771 | 8,054 |
kW-mo/yr
|
$18.47 |
| Electricity Fees | $4,843 | - |
|
- |
| Natural Gas | $5,200 | 520 |
MMBtu
|
$10.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $73,548 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,439 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7232: Replace existing hvac unit with high efficiency model | $42,830 | $89,250 |
$42,830
329,460
kWh
|
- | |
| 02 | 2.2522: Isolate hot or cold equipment | $814 | $2,000 |
$814
6,264
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,465 | $3,975 |
$949
11,974
kWh
|
$516
-
kW-mo/yr
|
|
| 04 | 4.425: Eliminate/reduce redundant inspections | $19,128 | $5,500 |
$19,128
110,032
kWh
|
- | |
| 05 | 4.426: Modify workload | $9,311 | $4,850 |
$9,311
118,953
kWh
|
- | |
| TOTAL RECOMMENDED | $73,548 | $105,575 |
$73,032
576,683
kWh
|
$516
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $28,439 | $10,350 |
$28,439
228,985
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs