Assessment Year | 2005 |
---|---|
Principal Product | hydraulic actuators |
NAICS | 332912: Fluid Power Valve and Hose Fitting Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
117,000
ft2
|
Annual Production | 30,000
pieces
|
Production Hrs. Annual | 6,090
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $324,062 | 3,772,747 |
kWh
|
$0.086 |
Electricity Demand | $143,226 | 11,472 |
kW-mo/yr
|
$12.48 |
Electricity Fees | $(-13,331.0) | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,634 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,080 | $787 |
$839
9,766
kWh
|
$241
-
kW-mo/yr
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $388 | $300 |
$301
3,504
kWh
|
$87
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $920 | $250 |
$717
8,345
kWh
|
$203
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,554 | $7,000 |
$5,490
63,945
kWh
|
$7,064
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,769 | - |
$2,158
25,010
kWh
|
$611
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $17,711 | $8,337 |
$9,505
110,570
kWh
|
$8,206
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $13,634 | $7,787 |
$6,329
73,711
kWh
|
$7,305
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs