Assessment Year | 2004 |
---|---|
Principal Product | Egg Flats |
NAICS | 322299: All Other Converted Paper Product Manufacturing |
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
50,600
ft2
|
Annual Production | 5,500
ton
|
Production Hrs. Annual | 8,280
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $173,000 | 2,509,028 |
kWh
|
$0.069 |
Electricity Demand | $32,049 | 4,872 |
kW-mo/yr
|
$6.58 |
Electricity Fees | $(-85,848.0) | - |
|
- |
Natural Gas | $389,504 | 56,742 |
MMBtu
|
$6.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,703 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,984 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.4154: Eliminate leaks in water lines and valves | $528 | $25 | - | - |
$307
-
MMBtu
|
$172
-
Tgal
|
$49
-
gal
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,952 | $1,300 |
$2,653
31,417
kWh
|
$299
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $255 | $281 |
$222
2,622
kWh
|
$33
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,953 | $3,825 |
$4,592
37,890
kWh
|
$361
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $6,736 | $2,500 | - | - |
$6,736
-
MMBtu
|
- | - | - | |
06 | 4.111: Add equipment/ operators to reduce production bottleneck | $1,766 | $1,500 | - | - | - | - | - | $1,766 | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,513 | $880 |
$1,513
17,918
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $18,703 | $10,311 |
$8,980
89,847
kWh
|
$693
-
kW-mo/yr
|
$7,043
-
MMBtu
|
$172
-
Tgal
|
$49
-
gal
|
$1,766 | ||
TOTAL IMPLEMENTED | $11,984 | $4,986 |
$4,388
51,957
kWh
|
$332
-
kW-mo/yr
|
$7,043
-
MMBtu
|
$172
-
Tgal
|
$49
-
gal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings |