Assessment Year | 2004 |
---|---|
Principal Product | Heat Treating |
NAICS | 332811: Metal Heat Treating |
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
16,200
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $93,824 | 761,218 |
kWh
|
$0.12 |
Electricity Demand | $16,744 | 2,088 |
kW-mo/yr
|
$8.02 |
Electricity Fees | $(-3,446.0) | - |
|
- |
Natural Gas | $127,654 | 19,030 |
MMBtu
|
$6.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $78,970 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $76,302 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $3,094 | $231 | - | - |
$3,094
-
MMBtu
|
- | - | |
02 | 2.1113: Reduce combustion air flow to optimum | $1,288 | $1,000 | - | - |
$1,788
-
MMBtu
|
$(-500.0) | - | |
03 | 4.821: Pay bills on time to avoid late fees | $392 | - | - | - | - | - | $392 | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,673 | $125 |
$2,574
18,159
kWh
|
$99
-
kW-mo/yr
|
- | - | - | |
05 | 2.2135: Repair and eliminate steam leaks | $3,618 | $4,000 | - | - |
$3,618
-
MMBtu
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,439 | $1,740 |
$1,385
9,772
kWh
|
$54
-
kW-mo/yr
|
- | - | - | |
07 | 2.7145: Install skylights | $2,237 | $300 |
$2,150
15,166
kWh
|
$87
-
kW-mo/yr
|
- | - | - | |
08 | 4.431: Train operators for maximum operating efficiency | $21,938 | $6,600 | - | - | - | $21,938 | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $431 | - |
$415
2,927
kWh
|
$16
-
kW-mo/yr
|
- | - | - | |
10 | 4.426: Modify workload | $41,860 | $19,000 | - | - | - | $41,860 | - | |
TOTAL RECOMMENDED | $78,970 | $32,996 |
$6,524
46,024
kWh
|
$256
-
kW-mo/yr
|
$8,500
-
MMBtu
|
$63,298 | $392 | ||
TOTAL IMPLEMENTED | $76,302 | $32,696 |
$3,959
27,931
kWh
|
$153
-
kW-mo/yr
|
$8,500
-
MMBtu
|
$63,298 | $392 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs