Assessment Year | 2002 |
---|---|
Principal Product | heat treating service |
NAICS |
n/a
|
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 32 |
Plant Area |
26,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,255 | 763,300 |
kWh
|
$0.12 |
Electricity Demand | $19,367 | 2,364 |
kW-mo/yr
|
$8.19 |
Electricity Fees | $(-549.0) | - |
|
- |
Natural Gas | $168,138 | 32,559 |
MMBtu
|
$5.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $426,893 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,431 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $2,878 | $5,000 | - | - |
$2,878
-
MMBtu
|
- | - | - | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,317 | $1,000 | - | - |
$4,317
-
MMBtu
|
- | - | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $3,903 | - |
$3,724
27,581
kWh
|
$179
-
kW-mo/yr
|
- | - | - | - | |
04 | 3.3131: Use evaporation to concentrate material | $3,478 | $5,500 | - | - | - |
$3,478
-
Tgal
|
- | - | |
05 | 4.111: Add equipment/ operators to reduce production bottleneck | $37,050 | $11,250 | - | - | - | - | - | $37,050 | |
06 | 4.731: Advertise product or service | $198,750 | $2,000 | - | - | - | - | $198,750 | - | |
07 | 4.111: Add equipment/ operators to reduce production bottleneck | $176,517 | $2,000 | - | - | - | - | $176,517 | - | |
TOTAL RECOMMENDED | $426,893 | $26,750 |
$3,724
27,581
kWh
|
$179
-
kW-mo/yr
|
$7,195
-
MMBtu
|
$3,478
-
Tgal
|
$375,267 | $37,050 | ||
TOTAL IMPLEMENTED | $44,431 | $16,750 |
$3,724
27,581
kWh
|
$179
-
kW-mo/yr
|
- |
$3,478
-
Tgal
|
- | $37,050 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs