| Assessment Year | 2002 |
|---|---|
| Principal Product | envelopes |
| NAICS |
n/a
|
| SIC | 2677: Envelopes |
| Sales Range | $100 M to 500M |
| # of Employees | 208 |
| Plant Area |
185,000
ft2
|
| Annual Production | 2,500,000,000
pieces
|
| Production Hrs. Annual | 6,048
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $495,067 | 6,572,711 |
kWh
|
$0.075 |
| Electricity Demand | $146,006 | 15,192 |
kW-mo/yr
|
$9.61 |
| Electricity Fees | $41,501 | - |
|
- |
| Natural Gas | $975 | 88 |
MMBtu
|
$11.08 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $107,933 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $98,680 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $2,567 | $3,850 |
$2,177
20,645
kWh
|
$390
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,580 | $350 |
$3,787
30,229
kWh
|
$573
-
kW-mo/yr
|
$(-780.0) | - | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $4,564 | $456 |
$3,869
36,750
kWh
|
$695
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7144: Install spectral reflectors / delamp | $2,122 | $3,375 |
$1,639
15,551
kWh
|
$483
-
kW-mo/yr
|
- | - | - | |
| 05 | 4.311: Schedule deliveries according to demand | $63,600 | $15,000 | - | - | - | $63,600 | - | |
| 06 | 4.625: Develop standard operating procedures | $31,500 | $9,240 | - | - | - | - | $31,500 | |
| TOTAL RECOMMENDED | $107,933 | $32,271 |
$11,472
103,175
kWh
|
$2,141
-
kW-mo/yr
|
$(-780.0) | $63,600 | $31,500 | ||
| TOTAL IMPLEMENTED | $98,680 | $24,590 |
$3,787
30,229
kWh
|
$573
-
kW-mo/yr
|
$(-780.0) | $63,600 | $31,500 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs