| Assessment Year | 2001 |
|---|---|
| Principal Product | tire replacement products |
| NAICS |
n/a
|
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 77 |
| Plant Area |
95,000
ft2
|
| Annual Production | 18,000,000
lb
|
| Production Hrs. Annual | 3,254
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $334,782 | 6,933,064 |
kWh
|
$0.048 |
| Electricity Demand | $232,396 | 44,388 |
kW-mo/yr
|
$5.24 |
| Electricity Fees | $67,891 | - |
|
- |
| Natural Gas | $94,179 | 8,733 |
MMBtu
|
$10.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,183 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,087 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $425 | $418 |
$331
3,177
kWh
|
$94
-
kW-mo/yr
|
- | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $12,586 | $240 |
$9,774
93,891
kWh
|
$2,812
-
kW-mo/yr
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,085 | $2,482 |
$841
8,077
kWh
|
$244
-
kW-mo/yr
|
- | - | |
| 04 | 4.513: Re-arrange equipment layout to reduce labor costs | $3,087 | $450 | - | - | $3,087 | - | |
| 05 | 4.323: Optimize lot sizes to reduce inventory carrying costs | $10,000 | $3,000 | - | - | - | $10,000 | |
| TOTAL RECOMMENDED | $27,183 | $6,590 |
$10,946
105,145
kWh
|
$3,150
-
kW-mo/yr
|
$3,087 | $10,000 | ||
| TOTAL IMPLEMENTED | $13,087 | $3,450 | - | - | $3,087 | $10,000 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs