Assessment Year | 2001 |
---|---|
Principal Product | opto-electronic components |
NAICS |
n/a
|
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
42,000
ft2
|
Annual Production | 250,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $292,930 | 4,812,533 |
kWh
|
$0.061 |
Electricity Demand | $120,994 | 10,405 |
kW-mo/yr
|
$11.63 |
Electricity Fees | $37,930 | - |
|
- |
Natural Gas | $5,061 | 463 |
MMBtu
|
$10.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $475,942 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,110 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7145: Install skylights | $650 | $1,600 |
$445
3,144
kWh
|
$205
-
kW-mo/yr
|
- | - | |
02 | 2.7144: Install spectral reflectors / delamp | $3,603 | $5,085 |
$2,691
20,877
kWh
|
$912
-
kW-mo/yr
|
- | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $35,295 | $60,000 |
$16,385
121,550
kWh
|
$18,910
-
kW-mo/yr
|
- | - | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,507 | - |
$4,627
35,490
kWh
|
$1,065
-
kW-mo/yr
|
$(-3,185.0) | - | |
05 | 2.8112: Combine utility meters | $100,007 | $60,200 | - | - | - | $100,007 | |
06 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $21,880 | $11,800 | - | - | - | $21,880 | |
07 | 4.431: Train operators for maximum operating efficiency | $312,000 | $100,000 | - | - | $312,000 | - | |
TOTAL RECOMMENDED | $475,942 | $238,685 |
$24,148
181,061
kWh
|
$21,092
-
kW-mo/yr
|
$308,815 | $121,887 | ||
TOTAL IMPLEMENTED | $6,110 | $5,085 |
$7,318
56,367
kWh
|
$1,977
-
kW-mo/yr
|
$(-3,185.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs