ITAC Assessment: LL0366
ITAC logo
ITAC Assessment: LL0366
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2012
Principal Product Skid Packages
NAICS 332313: Plate Work Manufacturing
SIC 3441: Fabricated Structural Metal
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 40,000
ft2
Annual Production 1,000
pieces
Production Hrs. Annual 8,400
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $89,950 1,211,110
kWh
Electricity Demand $63,390 5,943
kW-mo/yr
Electricity Fees $7,642 -
Natural Gas $7,416 834
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $40,621 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $18,167 $4,320 $17,304
232,991
kWh
- $862 - -
02 2.7224: Reduce space conditioning during non-working hours $12,261 $900 $11,679
157,248
kWh
- $582 - -
03 2.8123: Pay utility bills on time $4,597 $30 - - $4,597 - -
04 4.611: Begin a practice of predictive / preventative maintenance $4,042 $480 $2,421
32,598
kWh
- $121 - $1,500
05 2.7142: Utilize higher efficiency lamps and/or ballasts $429 $245 $173
2,324
kWh
$34
-
kW-mo/yr
$10 $212 -
06 2.7135: Install occupancy sensors $373 $840 $355
4,783
kWh
- $18 - -
07 2.7134: Use photocell controls $329 $140 $314
4,224
kWh
- $16 - -
08 2.6211: Conserve energy by efficient use of vending machines $263 $368 $250
3,360
kWh
- $13 - -
09 2.7111: Reduce illumination to minimum necessary levels $161 $115 $153
2,063
kWh
- $8 - -
TOTAL RECOMMENDED $40,621 $7,438 $32,648
439,591
kWh
$34
-
kW-mo/yr
$6,227 $212 $1,500
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs