Assessment Year | 2012 |
---|---|
Principal Product | Skid Packages |
NAICS | 332313: Plate Work Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
40,000
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,950 | 1,211,110 |
kWh
|
$0.074 |
Electricity Demand | $63,390 | 5,943 |
kW-mo/yr
|
$10.67 |
Electricity Fees | $7,642 | - |
|
- |
Natural Gas | $7,416 | 834 |
MMBtu
|
$8.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $40,621 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,167 | $4,320 |
$17,304
232,991
kWh
|
- | $862 | - | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $12,261 | $900 |
$11,679
157,248
kWh
|
- | $582 | - | - | |
03 | 2.8123: Pay utility bills on time | $4,597 | $30 | - | - | $4,597 | - | - | |
04 | 4.611: Begin a practice of predictive / preventative maintenance | $4,042 | $480 |
$2,421
32,598
kWh
|
- | $121 | - | $1,500 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $429 | $245 |
$173
2,324
kWh
|
$34
-
kW-mo/yr
|
$10 | $212 | - | |
06 | 2.7135: Install occupancy sensors | $373 | $840 |
$355
4,783
kWh
|
- | $18 | - | - | |
07 | 2.7134: Use photocell controls | $329 | $140 |
$314
4,224
kWh
|
- | $16 | - | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $263 | $368 |
$250
3,360
kWh
|
- | $13 | - | - | |
09 | 2.7111: Reduce illumination to minimum necessary levels | $161 | $115 |
$153
2,063
kWh
|
- | $8 | - | - | |
TOTAL RECOMMENDED | $40,621 | $7,438 |
$32,648
439,591
kWh
|
$34
-
kW-mo/yr
|
$6,227 | $212 | $1,500 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs