| Assessment Year | 2011 |
|---|---|
| Principal Product | Vegetable Oils |
| NAICS | 311224: Soybean and Other Oilseed Processing |
| SIC | 2079: Shortening, Table Oils, Margarine, and Other Edible Fats and Oils, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 225 |
| Plant Area |
90,000
ft2
|
| Annual Production | 350,000,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,085,751 | 17,891,811 |
kWh
|
$0.061 |
| Electricity Demand | $0.0 | 32,257 |
kW-mo/yr
|
$0.000 |
| Natural Gas | $2,739,788 | 451,105 |
MMBtu
|
$6.07 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $679,104 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $647,400 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2135: Repair and eliminate steam leaks | $627,674 | $22,250 | - |
$627,674
-
MMBtu
|
- | |
| 02 | 2.4226: Use / purchase optimum sized compressor | $25,792 | $5,600 |
$25,792
425,057
kWh
|
- | - | |
| 03 | 2.2511: Insulate bare equipment | $16,577 | $1,321 | - |
$16,577
-
MMBtu
|
- | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $3,635 | $810 |
$3,635
59,904
kWh
|
- | - | |
| 05 | 2.7135: Install occupancy sensors | $1,746 | $4,980 |
$1,746
28,780
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,513 | $1,050 |
$604
9,959
kWh
|
- | $908 | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,259 | $3,570 |
$1,259
20,744
kWh
|
- | - | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $530 | $919 |
$530
8,736
kWh
|
- | - | |
| 09 | 2.7111: Reduce illumination to minimum necessary levels | $378 | $390 |
$378
6,221
kWh
|
- | - | |
| TOTAL RECOMMENDED | $679,104 | $40,889 |
$33,944
559,401
kWh
|
$644,251
-
MMBtu
|
$908 | ||
| TOTAL IMPLEMENTED | $647,400 | $28,581 |
$2,241
36,924
kWh
|
$644,251
-
MMBtu
|
$908 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs