| Assessment Year | 2011 |
|---|---|
| Principal Product | Injected molded goods |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 12 |
| Plant Area |
30,000
ft2
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $48,009 | 591,000 |
kWh
|
$0.081 |
| Electricity Fees | $3,598 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,792 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,798 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 4.611: Begin a practice of predictive / preventative maintenance | $2,759 | $180 |
$1,259
14,414
kWh
|
- | - | $1,500 | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $1,768 | $60 |
$1,768
20,250
kWh
|
- | - | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,130 | $60 |
$1,130
12,943
kWh
|
- | - | - | |
| 04 | 2.7134: Use photocell controls | $740 | $90 |
$740
8,475
kWh
|
- | - | - | |
| 05 | 2.7111: Reduce illumination to minimum necessary levels | $362 | $320 |
$362
4,147
kWh
|
- | - | - | |
| 06 | 2.4322: Use or replace with energy efficient substitutes | $298 | $160 |
$298
3,418
kWh
|
- | - | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $223 | $40 |
$223
2,553
kWh
|
- | - | - | |
| 08 | 2.7135: Install occupancy sensors | $181 | $240 |
$181
2,074
kWh
|
- | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $178 | $105 |
$81
996
kWh
|
$6 | $91 | - | |
| 10 | 2.6211: Conserve energy by efficient use of vending machines | $153 | $195 |
$153
1,747
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $7,792 | $1,450 |
$6,195
71,017
kWh
|
$6 | $91 | $1,500 | ||
| TOTAL IMPLEMENTED | $6,798 | $535 |
$5,201
59,631
kWh
|
$6 | $91 | $1,500 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs