Assessment Year 2011
Principal Product Education
NAICS 611110: Elementary and Secondary Schools
SIC 8211: Elementary and Secondary Schools
Sales Range less than $500
k
# of Employees 100
Plant Area 50,000
ft2
Annual Production 200
pieces
Production Hrs. Annual 2,000
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $197,274 2,253,331
kWh
Natural Gas $8,324 1,043
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,632 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,610

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7224: Reduce space conditioning during non-working hours $10,506 $1,800 $10,506
120,000
kWh
- - - -
02 2.7135: Install occupancy sensors $2,820 $6,447 $2,820
32,214
kWh
- - - -
03 4.611: Begin a practice of predictive / preventative maintenance $2,760 $3,072 - - - $2,760 -
04 2.8112: Combine utility meters $2,504 $210 - $2,504 - - -
05 4.611: Begin a practice of predictive / preventative maintenance $1,581 $150 $81
920
kWh
- - - $1,500
06 2.6211: Conserve energy by efficient use of vending machines $1,071 $1,290 $1,071
12,230
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $890 $525 $490
4,980
kWh
- - $400 -
08 2.7111: Reduce illumination to minimum necessary levels $90 $80 $90
1,024
kWh
- - - -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $51 $30 $51
588
kWh
- - - -
10 2.7111: Reduce illumination to minimum necessary levels $90 $80 $90
1,024
kWh
- - - -
11 2.2511: Insulate bare equipment $269 $366 - - $269
-
MMBtu
- -
TOTAL RECOMMENDED $22,632 $14,050 $15,199
172,980
kWh
$2,504 $269
-
MMBtu
$3,160 $1,500
TOTAL IMPLEMENTED $4,610 $3,588 $81
920
kWh
- $269
-
MMBtu
$2,760 $1,500
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs