| Assessment Year | 2010 |
|---|---|
| Principal Product | Research |
| NAICS | 211111: Crude Petroleum and Natural Gas Extraction |
| SIC | 1311: Crude Petroleum and Natural Gas |
| Sales Range | less than $500 k |
| # of Employees | 20 |
| Plant Area |
70,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $413,449 | 6,856,800 |
kWh
|
$0.060 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $417,262 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $307 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $126,427 | $900 |
$126,427
2,096,640
kWh
|
- | |
| 02 | 2.9131: Install hydrogen fuel cell | $112,994 | $400,000 |
$112,994
1,873,872
kWh
|
- | |
| 03 | 2.7226: Use computer programs to optimize hvac performance | $82,693 | $100,000 |
$82,693
1,371,360
kWh
|
- | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $81,713 | $1,560 |
$81,713
1,355,113
kWh
|
- | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $8,816 | $597 |
$8,816
146,206
kWh
|
- | |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $1,771 | $850 |
$1,771
29,374
kWh
|
- | |
| 07 | 4.611: Begin a practice of predictive / preventative maintenance | $1,715 | $240 |
$215
3,562
kWh
|
$1,500 | |
| 08 | 2.7135: Install occupancy sensors | $615 | $690 |
$615
10,203
kWh
|
- | |
| 09 | 2.7134: Use photocell controls | $307 | $30 |
$307
5,097
kWh
|
- | |
| 10 | 2.6211: Conserve energy by efficient use of vending machines | $211 | $312 |
$211
3,494
kWh
|
- | |
| TOTAL RECOMMENDED | $417,262 | $505,179 |
$415,762
6,894,921
kWh
|
$1,500 | ||
| TOTAL IMPLEMENTED | $307 | $30 |
$307
5,097
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs