Assessment Year 2010
Principal Product Aluminum Extrusions
NAICS 331318: Other Aluminum Rolling, Drawing, and Extruding
SIC 3354: Aluminum Extruded Products
Sales Range $100
M
to 500
M
# of Employees 257
Plant Area 430,000
ft2
Annual Production 350,000,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,330,820 19,820,400
kWh
Natural Gas $2,349,940 225,970
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $108,830 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $90,249

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $88,374 $59,360 $88,374
1,286,480
kWh
-
02 4.611: Begin a practice of predictive / preventative maintenance $11,781 $4,070 - $11,781
03 2.7135: Install occupancy sensors $2,266 $1,800 $2,266
33,756
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,153 $10,605 $2,153
32,074
kWh
-
05 2.7224: Reduce space conditioning during non-working hours $1,875 $1,650 $1,875
27,930
kWh
-
06 2.7111: Reduce illumination to minimum necessary levels $1,079 $695 $1,079
16,072
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,067 $700 $460
6,657
kWh
$607
08 2.6211: Conserve energy by efficient use of vending machines $235 $319 $235
3,494
kWh
-
TOTAL RECOMMENDED $108,830 $79,199 $96,442
1,406,463
kWh
$12,388
TOTAL IMPLEMENTED $90,249 $61,010 $90,249
1,314,410
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs