Assessment Year | 2010 |
---|---|
Principal Product | Waste treatment |
NAICS | 562211: Hazardous Waste Treatment and Disposal |
SIC | 4953: Refuse Systems |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
760,000
ft2
|
Annual Production | 10,000
Tgal
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,624,735 | 46,328,094 |
kWh
|
$0.100 |
Natural Gas | $2,161,588 | 207,774 |
MMBtu
|
$10.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $342,251 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $337,474 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $323,997 | $61,880 |
$323,997
3,245,486
kWh
|
- | |
02 | 2.7224: Reduce space conditioning during non-working hours | $13,477 | $1,200 |
$13,477
135,000
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $1,741 | $2,100 |
$1,741
17,440
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,590 | $1,250 |
$831
8,322
kWh
|
$759 | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $923 | $530 |
$923
9,243
kWh
|
- | |
06 | 2.6211: Conserve energy by efficient use of vending machines | $523 | $546 |
$523
5,242
kWh
|
- | |
TOTAL RECOMMENDED | $342,251 | $67,506 |
$341,492
3,420,733
kWh
|
$759 | ||
TOTAL IMPLEMENTED | $337,474 | $63,080 |
$337,474
3,380,486
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs