| Assessment Year | 2010 |
|---|---|
| Principal Product | Environmental Services |
| NAICS | 562213: Solid Waste Combustors and Incinerators |
| SIC | 4953: Refuse Systems |
| Sales Range | $1 M to 5M |
| # of Employees | 35 |
| Plant Area |
200,000
ft2
|
| Annual Production | 14,600
Tgal
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,668 | 1,510,614 |
kWh
|
$0.065 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,982 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,231 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,056 | $1,870 |
$4,056
62,401
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $520 | $350 |
$216
3,326
kWh
|
$304 | |
| 03 | 2.7135: Install occupancy sensors | $175 | $330 |
$175
2,698
kWh
|
- | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $117 | $120 |
$117
1,800
kWh
|
- | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $114 | $167 |
$114
1,747
kWh
|
- | |
| TOTAL RECOMMENDED | $4,982 | $2,837 |
$4,678
71,972
kWh
|
$304 | ||
| TOTAL IMPLEMENTED | $4,231 | $2,200 |
$4,231
65,099
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs