Assessment Year | 2010 |
---|---|
Principal Product | Electric connectors |
NAICS | 334417: Electronic Connector Manufacturing |
SIC | 3678: Electronic Connectors |
Sales Range | $100 M to 500M |
# of Employees | 900 |
Plant Area |
400,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,059,625 | 31,877,600 |
kWh
|
$0.065 |
Natural Gas | $93,688 | 8,664 |
MMBtu
|
$10.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $92,942 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $89,071 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $44,220 | $15,480 |
$44,220
684,409
kWh
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $31,166 | $6,970 |
$31,166
482,364
kWh
|
- | - | |
03 | 2.2511: Insulate bare equipment | $13,685 | $3,250 | - |
$13,685
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,178 | $1,470 |
$903
13,981
kWh
|
- | $1,275 | |
05 | 2.6211: Conserve energy by efficient use of vending machines | $1,693 | $2,340 |
$1,693
26,208
kWh
|
- | - | |
TOTAL RECOMMENDED | $92,942 | $29,510 |
$77,982
1,206,962
kWh
|
$13,685
-
MMBtu
|
$1,275 | ||
TOTAL IMPLEMENTED | $89,071 | $25,700 |
$75,386
1,166,773
kWh
|
$13,685
-
MMBtu
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs