| Assessment Year | 2009 |
|---|---|
| Principal Product | Modular conveyoe belts |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 250 |
| Plant Area |
55,924
ft2
|
| Annual Production | 16,114
pieces
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $3,572,995 | 38,919,900 |
kWh
|
$0.092 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,306 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $42,707 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $26,101 | $6,360 |
$26,101
284,330
kWh
|
|
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $11,987 | $30 |
$11,987
130,580
kWh
|
|
| 03 | 2.2511: Insulate bare equipment | $3,253 | $4,564 |
$3,253
35,441
kWh
|
|
| 04 | 2.2511: Insulate bare equipment | $1,366 | $734 |
$1,366
14,879
kWh
|
|
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $802 | $779 |
$802
8,736
kWh
|
|
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $797 | $55 |
$797
8,683
kWh
|
|
| TOTAL RECOMMENDED | $44,306 | $12,522 |
$44,306
482,649
kWh
|
||
| TOTAL IMPLEMENTED | $42,707 | $11,688 |
$42,707
465,230
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs