Assessment Year 2009
Principal Product Plywood
NAICS 321912: Cut Stock, Resawing Lumber, and Planing
SIC 2439: Structural Wood Members, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 112
Plant Area 277,678
ft2
Annual Production 16,000,000
pieces
Production Hrs. Annual 4,500
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $549,764 7,575,600
kWh
Natural Gas $162,505 19,782
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $238,248 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $229,569

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Wood Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.2135: Repair and eliminate steam leaks $208,490 $16,797 - $208,490
-
MMBtu
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $12,944 $8,910 $12,944
178,362
kWh
- - -
03 4.611: Begin a practice of predictive / preventative maintenance $7,250 $1,410 $4,750
65,454
kWh
- - $2,500
04 2.7142: Utilize higher efficiency lamps and/or ballasts $6,138 $27,225 $6,138
84,575
kWh
- - -
05 2.4239: Eliminate or reduce compressed air usage $2,541 $894 $2,541
35,018
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $818 $525 $362
4,993
kWh
- $456 -
07 2.6211: Conserve energy by efficient use of vending machines $67 $156 $67
918
kWh
- - -
TOTAL RECOMMENDED $238,248 $55,917 $26,802
369,320
kWh
$208,490
-
MMBtu
$456 $2,500
TOTAL IMPLEMENTED $229,569 $27,798 $18,123
249,727
kWh
$208,490
-
MMBtu
$456 $2,500
Yearly Savings* Imp'd Cost* Electricity Usage Savings Wood Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs