Assessment Year | 2008 |
---|---|
Principal Product | Light fixtures |
NAICS | 335122: Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing |
SIC | 3646: Commercial, Industrial, and Institutional Electric Lighting Fixtures |
Sales Range | $1 M to 5M |
# of Employees | 42 |
Plant Area |
35,000
ft2
|
Annual Production | 2,600
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,430 | 285,200 |
kWh
|
$0.11 |
Electricity Fees | $1,156 | - |
|
- |
Natural Gas | $8,242 | 685 |
MMBtu
|
$12.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,919 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,424 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $8,543 | $2,810 |
$8,230
77,130
kWh
|
$313 | - | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $5,929 | $1,440 |
$5,712
53,529
kWh
|
$217 | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $2,949 | $1,716 |
$2,841
26,627
kWh
|
$108 | - | |
04 | 4.611: Begin a practice of predictive / preventative maintenance | $1,767 | $90 |
$257
2,413
kWh
|
$10 | $1,500 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,728 | $880 |
$1,665
15,609
kWh
|
$63 | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $701 | $10 |
$675
6,325
kWh
|
$26 | - | |
07 | 2.7135: Install occupancy sensors | $256 | $375 |
$247
2,313
kWh
|
$9 | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $46 | $156 |
$44
416
kWh
|
$2 | - | |
TOTAL RECOMMENDED | $21,919 | $7,477 |
$19,671
184,362
kWh
|
$748 | $1,500 | ||
TOTAL IMPLEMENTED | $9,424 | $2,410 |
$7,634
71,551
kWh
|
$290 | $1,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs