Assessment Year | 2008 |
---|---|
Principal Product | Sugar Mill Equipment |
NAICS | 333111: Farm Machinery and Equipment Manufacturing |
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
45,000
ft2
|
Annual Production | 75
pieces
|
Production Hrs. Annual | 5,356
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $110,756 | 1,386,952 |
kWh
|
$0.080 |
Electricity Demand | $45,301 | 5,393 |
kW-mo/yr
|
$8.40 |
Electricity Fees | $5,085 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,499 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,976 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,840 | $30 |
$3,717
46,615
kWh
|
- | $123 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,742 | $1,120 |
$3,622
45,429
kWh
|
- | $120 | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $2,155 | $456 |
$1,406
17,635
kWh
|
$680
-
kW-mo/yr
|
$69 | |
04 | 2.7135: Install occupancy sensors | $1,821 | $60 |
$594
7,456
kWh
|
$1,169
-
kW-mo/yr
|
$58 | |
05 | 2.4239: Eliminate or reduce compressed air usage | $641 | $433 |
$621
7,792
kWh
|
- | $20 | |
06 | 2.7224: Reduce space conditioning during non-working hours | $543 | $330 |
$526
6,593
kWh
|
- | $17 | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $494 | $478 |
$419
5,256
kWh
|
$59
-
kW-mo/yr
|
$16 | |
08 | 2.7134: Use photocell controls | $263 | $60 |
$187
2,345
kWh
|
$67
-
kW-mo/yr
|
$9 | |
TOTAL RECOMMENDED | $13,499 | $2,967 |
$11,092
139,121
kWh
|
$1,975
-
kW-mo/yr
|
$432 | ||
TOTAL IMPLEMENTED | $3,976 | $516 |
$2,000
25,091
kWh
|
$1,849
-
kW-mo/yr
|
$127 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs