Assessment Year | 2007 |
---|---|
Principal Product | Sliced meat |
NAICS | 311612: Meat Processed from Carcasses |
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $50 M to 100M |
# of Employees | 500 |
Plant Area |
230,000
ft2
|
Annual Production | 55,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,061,453 | 16,313,221 |
kWh
|
$0.065 |
Electricity Demand | $2,091 | 601 |
kW-mo/yr
|
$3.48 |
Electricity Fees | $72,553 | - |
|
- |
Natural Gas | $361,006 | 51,200 |
MMBtu
|
$7.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $129,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2441: Preheat boiler makeup water with waste process heat | $52,170 | $49,000 | - | - | - |
$52,170
-
MMBtu
|
- | |
02 | 2.4239: Eliminate or reduce compressed air usage | $33,682 | $1,600 |
$31,537
484,663
kWh
|
- | $2,145 | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $21,045 | $12,575 |
$19,705
302,823
kWh
|
- | $1,340 | - | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $16,900 | $1,500 | - | - | - |
$16,900
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,314 | $2,100 |
$1,300
19,973
kWh
|
$97
-
kW-mo/yr
|
$95 | - | $1,822 | |
06 | 2.6211: Conserve energy by efficient use of vending machines | $1,700 | $2,074 |
$1,482
22,776
kWh
|
$109
-
kW-mo/yr
|
$109 | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,030 | $451 |
$964
14,808
kWh
|
- | $66 | - | - | |
08 | 2.2511: Insulate bare equipment | $155 | $102 | - | - | - |
$155
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $129,996 | $69,402 |
$54,988
845,043
kWh
|
$206
-
kW-mo/yr
|
$3,755 |
$69,225
-
MMBtu
|
$1,822 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs